How attackers got into Osaki Electric: a VPN account without MFA and repeated password attempts at 1:30 a.m.Algonquin Dam cyberattack attempt: Illinois says staff blocked unauthorized access and kept full control of the Fox River damHow the Equinor and Skagerak Energi attacks happened: an Azure API Management flaw, Norway's NSM saysJava4Shell reaches the plant floor: Siemens Industrial Edge and Ignition SCADA exposed to CVE-2026-114938, with no Siemens fix yetRansomware halts smart meter production at Osaki Electric, the top meter supplier to Japan's power utilitiesEquinor hit by an "ongoing" cyber-attack as Norway's energy giant moves to neutralise the intrudersA perfect-10 SCADA flaw found by AI: the Circutor PowerStudio exploit sat on GitHub for three months before it got a CVEThe chlorine alarm went out by email just as Microsoft went down: 15 guests hurt at a German hotel pool1,266 ransomware attacks on industry in one quarter. Not one reached a control system, and plants stopped anywayHackers claim they took over an Italian heating plant. Italy's agency says it was a small system left exposed2,400 AI agents attacked a simulated water plant. Not one write reached the real controllerMaersk confirms: data was stolen from a leftover system. A ransomware gang demands $5 millionSiemens: an NTLM relay flaw in WinCC and PCS 7, and for several products no fix is plannedBrazil's biggest port confirms a cyberattack. Police raised the security level at the gatesHackers claim they took over an Italian heating plant. Italy's agency says it was a small system left exposed2,400 AI agents attacked a simulated water plant. Not one write reached the real controllerMaersk confirms: data was stolen from a leftover system. A ransomware gang demands $5 millionSiemens: an NTLM relay flaw in WinCC and PCS 7, and for several products no fix is plannedBrazil's biggest port confirms a cyberattack. Police raised the security level at the gates
Consulting site
ICS Cyber News
Thursday, 12 November 2026, Israel time

Siemens: a CVSS 9.8 Brotli flaw in Industrial Edge has no fix yet. CISA already listed it as exploited

Siemens published advisories for CVE-2026-111497, a Brotli decompression flaw known as Node2Shell, rated CVSS 9.8. It affects Industrial Edge Management apps and the RUGGEDCOM APE1808 platform. CISA added the underlying flaw to its Known Exploited Vulnerabilities list on 27 October.

12 Nov 2026, Israel time
Technicians inspect an industrial-edge gateway on a workbench. Illustrative, AI-generated.
Illustration
For the Industrial Edge apps, Siemens had published no fix yet. CISA had already added the underlying flaw to KEV on 27 October.

What Siemens published

On 30 October, Siemens published advisories for CVE-2026-111497 ("Node2Shell"), a Brotli decompression flaw rated CVSS 9.8.

It affects Industrial Edge Management apps and the RUGGEDCOM APE1808 platform. A related advisory is SSA-898633.

What is still unpatched

CISA had already added the underlying flaw to its Known Exploited Vulnerabilities list on 27 October.

For the Industrial Edge apps, Siemens had not published a fix yet. The draft coverage summarized the vendor guidance, for those apps, as stopping or uninstalling the affected application until a fix exists.

What the Brotli bug is, and which Edge apps have a build to move to

CVE-2026-111497 is a buffer overflow in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0. Siemens says a remote, unauthenticated attacker can, with a crafted compressed stream, corrupt adjacent decoder state, disclose memory, cause a denial of service, or potentially run code. It is filed as CWE-787. The upstream advice quoted in SSA-443410 is to update Brotli libraries or binaries in that range to 1.0.10, 1.1.1 or 1.2.1.

On Industrial Edge Management, Siemens says that if no management applications are installed, no action is required: the affected library is in the stack, but the affected functionality is not used or exposed (the same for IEDK). For Siemens-managed Industrial Edge Hub and Management Cloud, firewall and WAF protection was already in place, and the Hub itself was fixed on the central cloud service from 29 October 2026, with no user action needed. Data Flow Monitoring versions before V3.0.18 should update to V3.0.18 or later. Cloud Connector Configurator versions before V1.24.3 should update to V1.24.3 or later. Common Configurator on Device (all versions) still had no fix in the advisory; Siemens' guidance is to stop that app until one arrives. A 6 November update added fixes for several configurators and added DataXess Configurator as affected.

If an Edge device still has to run an unpatched configurator, can you stop that one app without taking the rest of the device offline?