How attackers got into Osaki Electric: a VPN account without MFA and repeated password attempts at 1:30 a.m.Algonquin Dam cyberattack attempt: Illinois says staff blocked unauthorized access and kept full control of the Fox River damHow the Equinor and Skagerak Energi attacks happened: an Azure API Management flaw, Norway's NSM saysJava4Shell reaches the plant floor: Siemens Industrial Edge and Ignition SCADA exposed to CVE-2026-114938, with no Siemens fix yetRansomware halts smart meter production at Osaki Electric, the top meter supplier to Japan's power utilitiesEquinor hit by an "ongoing" cyber-attack as Norway's energy giant moves to neutralise the intrudersA perfect-10 SCADA flaw found by AI: the Circutor PowerStudio exploit sat on GitHub for three months before it got a CVEThe chlorine alarm went out by email just as Microsoft went down: 15 guests hurt at a German hotel pool1,266 ransomware attacks on industry in one quarter. Not one reached a control system, and plants stopped anywayHackers claim they took over an Italian heating plant. Italy's agency says it was a small system left exposed2,400 AI agents attacked a simulated water plant. Not one write reached the real controllerMaersk confirms: data was stolen from a leftover system. A ransomware gang demands $5 millionSiemens: an NTLM relay flaw in WinCC and PCS 7, and for several products no fix is plannedBrazil's biggest port confirms a cyberattack. Police raised the security level at the gatesHackers claim they took over an Italian heating plant. Italy's agency says it was a small system left exposed2,400 AI agents attacked a simulated water plant. Not one write reached the real controllerMaersk confirms: data was stolen from a leftover system. A ransomware gang demands $5 millionSiemens: an NTLM relay flaw in WinCC and PCS 7, and for several products no fix is plannedBrazil's biggest port confirms a cyberattack. Police raised the security level at the gates
Consulting site
ICS Cyber News
Thursday, 12 November 2026, Israel time

Energy SCADA software: critical auth and SQL flaws in PowerSYSTEM Center, CISA says

CISA published two bugs in Subnet PowerSYSTEM Center: incorrect authorization and SQL injection in the report designer. Affected lines include the 2020, 2024 and 2026 versions in the ranges CISA lists. CISA said there is no known public exploitation, and the issues are not remotely exploitable without an authenticated foothold.

12 Nov 2026, Israel time
Operators in an energy SCADA control room with a wall mimic panel. Illustrative, AI-generated.
Illustration
CISA says no known public exploitation and the issues are not remotely exploitable without an authenticated foothold. The reporter is Chinmay Patel of Digital Boundary Group.

What CISA published

Two bugs: CVE-2026-63017 (incorrect authorization) lets a low-privileged authenticated user reach admin-only resources. CVE-2026-63774 (SQL injection in the report designer) lets an authenticated user run unauthorized SQL.

Affected lines include PowerSYSTEM Center 2020, 2024 and 2026 in the version ranges CISA lists. The advisory is dated 3 November in the drafts (ICSA-26-307-01).

The fix, and what CISA does not claim

Subnet's fix path is version-specific updates (2020 Update 30, or 2026 Update 1.1 depending on branch). Interim advice includes monitoring user activity, disabling F12 developer tools for Client Access Server users, and cutting off report-designer access if you cannot patch yet.

CISA says no known public exploitation and the issues are not remotely exploitable without that authenticated foothold. Reporter: Chinmay Patel of Digital Boundary Group.

The scores, the CWE labels, and the exact version ranges

CISA files CVE-2026-63017 as CWE-863 (incorrect authorization) and CVE-2026-63774 as CWE-89 (SQL injection). Both are scored CVSS v3.1 9.0 and CVSS v4.0 9.4 in the advisory, with an adjacent-network, low-privilege authenticated vector (AV:A, PR:L). That matches the earlier point that these are not remotely exploitable without a foothold.

The affected ranges are written more tightly than the product-year labels: PowerSYSTEM Center 2020 at 5.29.x and earlier is listed for CVE-2026-63017 only; 2024 from 6.0.x through 6.2.x, and 2026 from 7.0.x through 7.1.x, are listed for both bugs. CISA places the product in critical manufacturing and energy, deployed worldwide, with the vendor based in Canada.

If a report-designer account can reach the database, which other authenticated roles on that same server can still open it?