A US utility regulator tells grid companies to look for hidden radios inside solar inverters
On 5 November the Pennsylvania Public Utility Commission issued a cybersecurity advisory on foreign-made, internet-connected power inverters. It said US officials have investigated Chinese-made inverters and batteries after finding undocumented communication parts, such as embedded cellular radios. The letter is a set of recommendations to the utilities.
What the Pennsylvania PUC wrote
On 5 November, the Pennsylvania Public Utility Commission issued a cybersecurity advisory on foreign-made, internet-connected power inverters.
It said US officials have investigated Chinese-made inverters and batteries after finding undocumented communication parts, such as embedded cellular radios, that could allow remote access outside the channels the utility approved.
What it points to, and what it is not
The advisory points to the EU, which now restricts EU funding for projects using high-risk inverter suppliers, and it names the dependence on vendors like Huawei and Sungrow, some of which (or their cloud managers) have remote access to the installed devices, according to the letter.
It also said one home inverter is a small risk, but virtual power plants pool thousands of them through one vendor cloud, and a compromise of that cloud API could hit reliability across a distribution system. The letter is a set of recommendations to the utilities, not a report of a confirmed attack in Pennsylvania.
The protocols the letter wants wrapped, and the paperwork it asks for
The Pennsylvania PUC advisory tells utilities to restrict clear-text, unauthenticated inverter protocols, and it names standard Modbus RTU/TCP and SunSpec as examples, through firewalls, allow-lists and port filtering. It then tells them to move toward secure protocols such as IEEE 1547.3, Modbus Secure, or DNP3 Secure Authentication.
It also asks operators to keep both software and hardware bills of materials (SBOMs and HBOMs) for inverter hardware, firmware and embedded communications modules, so unvetted changes are easier to spot. For telemetry-only environments, it recommends unidirectional gateways or data diodes, to cut the path for command injection. It tells utilities to document every inverter path, including Wi-Fi, cellular and vendor portals, and to drop the ones that are not needed. The letter also wants pre-deployment tests aimed at undocumented communication paths, hidden hardware, or rogue cellular radios.
If a feeder already has thousands of inverters talking Modbus in the clear, which of those links can you put behind a diode first?